加氢装置Hydrogenation unit

Time:2017年07月10日    TO:佚名    From:本站原创    Hit:    


Special hydrogenated corrosion inhibitor

Performance Introduction

High temperature, high pressure and resisting hydrogen are outstanding features of hydrogenation unit, H2S, NH4C1 and other compounds may generate due to the purposes of process to remove S, N and O and other non-ideal components from hydrocarbon, and there is certainly serious H2S-HCl-NH3-H2O corrosion appeared in the condensing and cooling system on the roof of fractionating system tower.

Special hydrogenated corrosion inhibitor can create a layer of dense monomolecular adsorptive and protective film on metal surface to prevent corrosion medium directly contacting metal surface, and mitigate hydrogen corrosion blistering.

It can ensure that corrosion inhibitor is free of various ions can cause material to suffer from hydrogen brittleness by unique production process and ions removal technology, and can effectively prevent materials from hydrogen brittleness, avoid the hydrogen brittleness hidden danger and hydrogen corrosion of hydrogenation unit and ensure the safe and stable operation of unit.

It can effectively inhibit the corrosion of hydrogenation unit, and has no influence on the oil quality of this device and downstream unit at the corrosion rate lower than 0.02mm/a (carbon steel) (1) if the recommended quantity is infused into system. 



Special corrosion and scale inhibitor for high-pressure air cooler

Performance Introduction

a: Scale formation and under-scale corrosion

Materials fed into hydrogenation unit often contain sulfur, nitrogen and chlorine, its reaction effluent contains H2S, NH3, HCl and other corrosion medium after the hydrogenation reaction. These substances will generate ammonium hydrosulfide, ammonium chloride, etc. due to mutual effect. The sublimation temperature of ammonium hydrosulfide and ammonium chloride is relatively low, therefore effluent often generates solid deposition and scale of ammonium hydrosulfide and ammonium chloride, etc. in the air-cooling tubes and downstream equipment pipelines in the process of cooling by in high pressure air cooler. A plenty of ammonium hydrosulfide, ammonium chloride and other salt scales adheres to the wall of equipment pipelines, it will cause equipment pipelines being blocked and under-scale corrosion, further resulting in relatively serious blocking and corrosion on the tubes of high pressure air cooler and downstream equipment pipelines and affecting the normal operation of equipment.

b: H2S-NH3-HCL-H2O corrosion

H2S-NH3-HCL-H2O corrosion often appears because ammonium hydrosulfide, ammonium chloride can solve in water and air cooler is cleaned with water from its upstream. Such corrosion appears at the temperature from 38 to 204, which is just the common operating range of such air coolers.

Special corrosion and scale inhibitor for high-pressure air cooler belongs to high molecular compound, which can effectively disperse ammonium hydrosulfide, ammonium chloride and other salt scales adhered on the wall of pipelines, inhibit the formation of new salt scales and prevent the occurrence of under-scale corrosion, such corrosion and scale inhibitor can also effectively inhibit H2S-NH3-HCL-H2O corrosion. It can effectively form a layer of protective film on metal surface, which can not only inhibit the scale corrosion on high pressure air cooler, but also inhibit the corrosion on downstream equipment caused from ammonium hydrosulfide, ammonium chloride. 


Special corrosion and scale inhibition and decoking agent for hydrogenation unit

Performance Introduction

At present, the coking problem of heat exchanger is mainly by the following 2 methods: Firstly by mechanical method, auxiliary equipment can be often used to improve technological process and operating patch; Secondly by chemical method, a certain quantity of different types of scale and polymerization inhibitor are often added into hydrogenated raw oil to inhibit and delay the formation of coked scale in raw oil heat exchanger. Scale inhibition and decoking agent has advantages of no change in technological process, no influence on normal operation, simple infusion, low capital input, etc., it has become the most economic and effective method to solve the coking problem of hydrogenated raw oil heat exchanger.

In light of different features of specific hydrogenation units such as gasoline and diesel hydrogenation units, wax oil hydrogenation unit, residual oil hydrogenation unit and hydrocracking unit, scale inhibition and decoking agent can be divided into (Type I) suitable diesel hydrogenation unit, (Type II) for hydrocracking unit, (Type III) for wax oil hydrogenation unit, and (Type IV) residual oil hydrogenation unit. Its components can be adjusted to achieve the best effect based on the processing features and scale formation mechanism of each unit. 


Special high efficient polymerization and inhibitor for hydrogenation unit

Performance Introduction

It has very strong ability to catch active free radicals, clean up, disperse, etc., can effectively interrupt the polymerization of free radicals and the chain addition polymerization of alkadiene, inhibit the chain occurrence and constant polymerization of free radical chain reaction, improve the yield of units, efficiency of heat exchanger and normal operation of reactor, and prolong the optional cycle of unit.

This product is free of toxicity and has outstanding heat-resistant and light stability, better compatibility, low volatility and no influence on the staining and properties of product, it can play the better polymerization inhibition effect within the boarder temperature (maximum allowable temperature above 300) and meanwhile effectively inhibit the coking of reactor within the boiling range from 140 to 290.

This product as a kind of safe and environment-friendly product is free of metal, halogen compounds, sulfur phosphine, etc., and it is easily used and has no negative influence on the subsequent catalyzer, product distribution, etc.